LED Street Light Global Certification & Compliance Guide
As a specialized outdoor lighting product, street lights operate in harsh environments and directly affect public safety.Entry requirements worldwide are far stricter than for ordinary indoor lamps.From EU CE, North American UL/FCC, Saudi SASO energy efficiency, to Australia SAA — each market has its own dedicated standards and special rules.
For manufacturers, understanding these requirements and planning a smart certification strategy can:
- Avoid cargo seizure, return or rejection
- Greatly shorten time-to-market
- Control compliance costs
- Help your street lights successfully enter global markets
01 Global Certification Map: Street Light Export Overview
Street light certification focuses on safety, EMC, IP rating, surge immunity, and energy efficiency.
表格
| Market | Mandatory Certification | Key Standards | Core Scope | Special Notes |
|---|---|---|---|---|
| EU | CE | LVD: EN 60598-2-3EMC: EN 55015, EN 61547RoHS, ErP | Safety, EMC, harmonics, surge, IP, energy label | Special tests for IP, surge, wind load |
| USA | UL 1598 Test Report / UL CertificationFCC | UL 1598, UL 8750FCC Part 15B | Safety, fire resistance, temperature rise, EMI | Amazon requires UL 1598; outdoor waterproof critical |
| Canada | cUL | CSA C22.2 No. 250.0 | Same as US; local voltage & marking | cULus mark covers both US & Canada |
| Saudi Arabia | SASO + IECEE | SASO 2927 (energy efficiency)<IEC 60598 | Energy rating, safety | Arabic label; official template from Jan 2025 |
| Australia / NZ | SAA + RCM | AS/NZS 60598.2.3 | Safety, EMC | 230V/50Hz, outdoor installation rules |
| China | CQC (voluntary) | GB 7000.1, GB 7000.203 | Safety, EMC, surge | Widely accepted for government projects |
| International | CB | IEC 60598-2-3 | Basic safety; easy conversion | 54 member countries |
Key Insight:Street lights are outdoor fixed luminaires and require dedicated standards:EN 60598-2-3 (EU), UL 1598 (US), AS/NZS 60598.2.3 (AU)with extra focus on IP rating, surge immunity, wind load, and optical performance.
02 In-depth Analysis of Major Markets
EU Market: CE + EN 60598-2-3 (Mandatory)
CE is legally required for street lights exported to the EU.
-
LVD + EN 60598-2-3
- IP rating (usually IP65 or higher)
- Surge immunity: line‑line 2kV, line‑earth 4kV (EN 61547)
- Wind load test
- Temperature rise test
-
EMC: EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3
-
ErP: ≥ 85 lm/W, standby ≤ 0.5W, EPREL registration
-
RoHS: Restriction of hazardous substances
Note: Wireless control (Zigbee, LoRa, NB‑IoT) requires RED Directive testing.
North America: UL 1598 — Safety Standard for Street Lights
In the US, street lights are fixed outdoor luminaires and must comply with UL 1598 + UL 8750 for LED.
Key tests:
- Normal & abnormal temperature rise
- Shock & fire protection
- Mechanical strength & wind load
- Flammability of plastic parts
- IP waterproof test
FCC:
- Normal: FCC SDoC (Part 15B)
- Wireless: FCC ID required
Saudi Arabia: SASO 2927 (Energy Efficiency)
SASO 2927 is the dedicated standard for street lighting.
Key requirements:
- Color temperature restriction removed in latest amendment
- 1–6 star energy rating
- Official unified report template mandatory from Jan 1, 2025
- Arabic label required
Certification modes:
- COC per shipment: 0.45% of FOB value (min ~CNY 1,950)
- Annual registration: valid 1 year
Australia: SAA Certification
Based on AS/NZS 60598.2.3:
- IP rating
- Impact test (hail simulation)
- Temperature rise, abnormal test
- Glow wire, ball pressure, needle flame test
Lead time: 4–6 weeks.
China: CQC Certification
Street lights are not in the CCC mandatory list.CQC certification is widely trusted for government & large projects.
Standards:GB 7000.1, GB 7000.203, GB/T 17743, GB 17625.1, GB/T 18595
03 Cost & Timeline Reference
表格
| Certification | Cost | Lead Time | Samples |
|---|---|---|---|
| EU CE (LVD+EMC+RoHS) | ¥8,000 – 15,000 | 7–10 days | 2–3 pcs |
| US UL 1598 Test Report | ¥1,000 – 3,000 | 7–10 days | 2–4 pcs |
| US FCC SDoC | ¥1,500 – 3,500 | 7–10 days | 2–3 pcs |
| Saudi SASO COC | 0.45% of FOB | 1–2 weeks | As needed |
| Australia SAA | ¥6,000 – 15,000 | 4–6 weeks | 2–4 pcs |
| CB Certification | ¥10,000 – 20,000 | 3–4 weeks | 2–3 pcs |
Cost factors:
- Product complexity (smart, dimming, wireless)
- Extra tests: surge, IEC 62471 photobiological safety
- Series model coverage
- Lab accreditation
Sample requirement:2–4 complete production units representing final mass product.
04 GTG One-Stop Solution: Your Efficient Compliance Partner
GTG Group provides full‑service certification for street lights:
- Pre‑assessment in the design phase
- EU CE, North America UL/FCC, Saudi SASO, Australia SAA, CB conversion
- Expertise in EN 60598-2-3, UL 1598, AS/NZS 60598.2.3, SASO 2927
- Higher first‑pass rate, shorter lead time
- CB conversion to reduce redundant testing
05 FAQ
Q1: Difference between CE for street lights and general lamps?
A1: Street lights use EN 60598-2-3, with extra tests for IP rating, surge immunity, wind load not required for indoor lamps.
Q2: UL Certification vs. UL Test Report?
A2:
- UL Certification: Full system + factory audit + UL mark; high cost, long lead time.
- UL Test Report: Test only; fast & low cost; for e‑commerce platforms only.
Q3: New SASO 2927 rules for Saudi Arabia?
A3: From Jan 1, 2025, only official unified templates are accepted. Color temperature limit (3000–6000K) has been removed.
Q4: Surge test requirements for street lights?
A4: Per EN 61547:
- Line to line: 2 kV
- Line to earth: 4 kVSimulates lightning impact.
Q5: Special rules for smart street lights?
A5: Wireless functions require:
- EU: RED
- US: FCC IDThermal performance may also be affected.
Q6: CQC vs. CCC for China?
A6: Street lights do NOT need CCC.CQC is voluntary but widely recognized for government projects.
Q7: How long are certificates valid?
A7:
- CE: Valid if standard & product unchanged
- UL Test Report: Valid if standard unchanged
- SASO registration: 1 year
- CQC: Needs annual supervision
- CB: >3 years may require review
Online Message
- LED Street Light Global Certification & Compliance Guide
- Desk Lamp Global Certification & Export Compliance Guide
- Downlight Global Certification & Export Compliance Guide
- Emergency Light Global Certification & Export Compliance Guide
- Complete Certification Guide for Stage Lighting Export to Global Markets
- LED Panel Light Global Export Certification & Compliance Guide
- CE-LVD Test Report for Luminaires: Your Safety Passport to the European Market
- UL 1598 Test Report: The Market Access Pass for Luminaires in North America
- IEC 60598: The Global Safety Standard for Lighting Products
- UL Certification for LED Panel Lights: North America Market Access Guide