CCC Confirmation Inspection Report for Lighting: Test Items & Application Process
I. What is a Confirmation Inspection Report?
Confirmation inspection refers to sampling inspection conducted to verify that certified products continue to comply with the certification basis standards. Meanwhile, periodic confirmation inspection of key components is regular sampling inspection performed to verify that the quality characteristics of key components consistently meet certification standards and/or technical requirements.
Confirmation inspection shall be carried out in accordance with the parameters and methods specified in the standards, under the required ambient conditions. The sampling frequency of confirmation inspection can be based on production batches or fixed time intervals, with the maximum interval not exceeding one year. This week, we will introduce the CCC Confirmation Inspection Report for Lighting Products—let’s dive in!
II. Routine Inspection and/or Confirmation Inspection
Factories shall establish and maintain documented procedures to control the routine inspection and/or confirmation inspection of final products. The inspection procedures must comply with specified requirements, covering content such as inspection frequency, items, scope, methods, and judgment criteria. Factories shall implement and retain relevant inspection records.
For inspections entrusted to external institutions, factories must ensure the external institution’s competence meets inspection requirements and retain evidence of competence evaluation (e.g., laboratory accreditation certificates).
III. Test Items for Lighting CCC Confirmation Inspection Report
| Test Item | Corresponding Standard Clause | Test Method |
|---|---|---|
| 1. Earthing Continuity | GB/T 7000.1 Clause 7 | Conducted in accordance with standard requirements |
| 2. Dielectric Strength or Insulation Resistance | GB/T 7000.1 Clause 9.3 + Clause 10 | Conducted in accordance with standard requirements |
| 3. Marking | GB/T 7000.1 Clause 3 | Verified against type test photos |
| 4. Tensile Test (for lighting with wiring devices) | GB/T 7000.1 Clause 5.2.10.3 | Tested by pulling the power cord with a dynamometer |
| 5. Distance Between Lamp Control Gear and Mounting Surface | GB/T 7000.1 Clause 4.16.1 | Conducted in accordance with standard requirements |
| 6. Heat Resistance & Fire Resistance | GB/T 7000.1 Clause 13 | Conducted in accordance with standard requirements |
IV. Application Process for CCC Confirmation Inspection Report
- Test Consultation
- Business Quotation
- Fill in Test Application Form (Provide product data)
- Sample Submission
- Case Initiation
- Testing Execution
- Report Issuance
Choose Professionalism, Choose Peace of Mind. GTG Testing Group specializes in lighting testing and certification. With complete testing equipment and profound industry experience, we provide full-cycle technical support for your lighting products, helping you efficiently pass compliance tests and maintain market access advantages.
CCC Certification for Recessed Downlights: Application Documents & Key Compliance Notes
Lighting CCC Confirmation Inspection Report: Core Test Items & Compliance Process/a>
Online Message
- Solar Lights & ERP Certification: Complete EU Compliance Guide
- Light + Building 2026 Review & EU Lighting Compliance Guide
- Interactive Outdoor Lights – EU Compliance & Certification Guide
- LED Outdoor Lighting: Europe's Mature Mainstream & Retail Access Threshold
- Solar Outdoor Lights: Europe's Green Trend & Retail Success with Costco & Home Depot
- Global Certification Requirements for Sky Light / Northern Light Projector Lamps
- Downlight IES Test Report – Complete Guide for Export & Project Bidding
- IEC 62471 Photobiological Safety Testing for Cameras
- IEC 62471 Photobiological Safety Testing for Projectors
- Photobiological Safety Testing: The Mandatory Gateway for Global LED Lighting