Welcome to Guangdong Meide Testing Technology Co., Ltd.!

Testing Lab of Lighting Products

Guangdong Meide Testing Technology Co., Ltd.

Guangdong Meide Testing Technology Co., Ltd.Location:Home > News

Return

Stage Light Distribution Testing: Core Performance Validation for Professional Stage Lighting

When stage lights turn on, how beams focus precisely on performers and light spots cover backdrops evenly—over 60% of these effects are determined by the luminaire’s optical design. A scientific light distribution test report is the authoritative endorsement of top-tier stage light performance.

Stage light distribution testing quantifies a luminaire’s spatial light intensity distribution via precision instruments, plotting luminous intensity distribution curves and generating IES/LDT files. These data serve as the core basis for lighting designers to conduct visual programming and effect previews, directly determining whether the luminaire can accurately realize the director’s artistic vision.


01 Why Is Stage Light Distribution Testing Indispensable?

Stage lighting is far more than just "illumination"—it is a core artistic tool for shaping space, rendering emotions, and guiding the audience’s gaze. Light distribution testing is the scientific method that standardizes, digitizes and predicts this artistic expressiveness.

Using professional equipment such as goniophotometers and imaging colorimeters, it comprehensively measures parameters including light intensity, illuminance, color temperature, and color rendering of stage lights in all directions in a dark room. The generated luminous intensity distribution curves and IES files can be directly imported into professional lighting design software such as MA 3D and WYSIWYG, enabling what-you-see-is-what-you-get (WYSIWYG) programming and preview.

For manufacturers, this report is a diagnosis for product R&D, objectively verifying whether the optical design meets standards and optimizing the lens and reflector system. For buyers and lessors, it is an objective basis for product selection, enabling precise comparison of hard indicators such as beam angle, uniformity, and peak light intensity of luminaires from different brands, avoiding on-site effect gaps caused by "subjective" procurement.


02 Which Stage Luminaires Require Light Distribution Testing?

Virtually all professional stage luminaires for live performances need their core performance verified and calibrated through light distribution testing.

1. Conventional Stage Luminaire Series

  • Profile Spotlights: Test the uniformity of light spots, edge sharpness, and imaging quality after passing through gobos.
  • Moving Head Lights: Test the optical axis stability and light spot consistency during full-range horizontal/vertical movement.
  • Beam Lights: Focus on testing the peak light intensity, beam divergence rate, and long-distance projection capability of their ultra-narrow beam angles.
  • Wash Lights: Core evaluation of color mixing uniformity, color saturation, and smooth transition effects for large-angle wall washing.

2. LED Imaging Lights & Cine Lights

These high-performance luminaires require strict testing of illuminance uniformity (usually >90%), color temperature consistency, and the stability of color rendering index (CRI) at different brightness levels.

3. Outdoor Performance & Architectural Landscape Lighting Luminaires

Such as large floodlights and media facade lights—in addition to light distribution, anti-glare rating and light pollution control data must be evaluated to meet environmental protection requirements.


03 Core Testing: Detailed Explanation of Stage Light Special Assessment Items

Stage light testing goes far beyond basic light distribution—it is a multi-dimensional evaluation system tailored to the dynamic and colorful characteristics of stage lighting.

Testing Category Core Evaluation Parameters Significance for Stage Effects
Basic Light Distribution Luminous intensity distribution curve, beam angle (half-peak angle), light intensity distribution, IES file Determines beam shape and coverage; the foundational data for lighting programming.
Photometry & Colorimetry Central illuminance, luminous flux, correlated color temperature (CCT), color rendering index (CRI) Determines brightness and the authenticity of color reproduction, ensuring accurate artistic expression.
Uniformity & Consistency Light spot illuminance uniformity, spatial color temperature uniformity Influences image texture; avoids "hot spots" or color unevenness in light spots.
Dynamic Characteristics Color temperature shift during dimming, flicker index Ensures color stability during brightness changes and avoids flicker in video shooting.
Special Functions Changes in light distribution with prism/gobo effects, gobo imaging clarity Verifies the actual optical performance of special effect functions.

04 Application Process & Sample Requirements

Obtaining an authoritative stage light distribution report requires following a professional process and preparing compliant samples.

Step 1: Pre-Consultation & Technical Disclosure

Clarify the luminaire type, testing purpose (R&D verification, bidding, certification), and applicable standards (national, European, or industry-specific) with the testing institution’s engineers.

Step 2: Sample Preparation & Shipment

Prepare 1-2 fully functional representative samples and ensure:

  • The luminaire is in optimal optical condition (clean lenses, smooth focusing mechanism).
  • Equipped with standard power supplies and signal cables, and can stably receive DMX signals.
  • Provide a list of key working modes (e.g., commonly used colors, gobos, prism combinations) for testing core application scenarios.

Step 3: Laboratory Systematic Testing

In a dark room, the luminaire is installed on a goniophotometer to conduct a full set of tests for basic white light mode, RGBW color mixing, dynamic functions and other states in sequence.

Step 4: Data Analysis & Report Delivery

Engineers process the test data and generate a complete report including luminous intensity distribution curves, IES files, key parameter tables, and professional interpretation.


05 Key Focus: Cost, Cycle & Professional Recommendations

The cost and cycle of stage light distribution testing are far higher than those of ordinary lighting luminaires due to its complexity, and need to be evaluated based on specific requirements.

Cost Composition

Mainly including basic testing fees and additional project fees. The market reference price for basic light distribution testing of a conventional moving head profile light is usually RMB 1,000 to 8,000. Costs will increase if additional tests such as multi-color temperature testing, dynamic dimming evaluation, and gobo analysis are required.

Testing Cycle

With complete samples and documents, a full set of tests and report issuance usually takes 5 to 10 working days. The cycle for complex luminaires or urgent requests needs to be negotiated separately.

Professional Value of GTG Testing

We have a professional dark room that can accommodate large moving head lights and a high-precision fast goniophotometer, capable of accurately capturing the optical performance of dynamic luminaires. Our engineers are familiar with the stage lighting industry and can provide performance interpretation and optimization suggestions beyond raw data, helping you not only obtain a report but also enhance product competitiveness.


06 Frequently Asked Questions (FAQs)

Q: What is an IES file? Why do lighting designers need it?

A: An IES file is a standard format file that records the spatial light intensity distribution data of a luminaire. After importing it into preview software such as MA 3D and Capture, lighting designers can simulate the 1:1 real irradiation effect of the luminaire on a virtual stage, including light and shadow, brightness, and light spot shape. This enables precise programming and effect debugging, avoiding the cost of on-site trial and error.

Q: Our luminaire has multiple colors and gobos—do we need to test all of them?

A: No, full-mode testing is unnecessary and costly. The standard practice is to test the baseline white light mode (the most commonly used), then select representative RGBW color mixing modes and 1-2 most frequently used gobo/prism modes for testing. This is sufficient to characterize the main optical performance of the luminaire. Our engineers will assist you in formulating the most cost-effective testing plan.

Q: Are there any special requirements for the installation state of the luminaire during testing?

A: The requirements are strict and critical. The luminaire must be installed in the actual usage mode. For example, moving head lights need to be tested at their "zero position" for beam performance; outdoor floodlights need to be fixed at the designed elevation angle. Any installation deviation will lead to data distortion. Please confirm the installation details with our engineers before testing.

Q: Does a light distribution test report have a validity period?

A: The report itself has no mandatory validity period, but it is only valid for the specific model and firmware version submitted for testing. Once the product undergoes optical-related design changes, such as replacing the light source module, modifying the optical lens, or upgrading the dimming algorithm, the original report becomes invalid and re-testing is required to obtain a new report.


In an era where performing arts and technology are deeply integrated, a precise stage light distribution test report is no longer just a technical document. It is a trust bridge connecting luminaire manufacturers, lighting designers, and the final stage effect, and the cornerstone of safeguarding artistic creativity with scientific data. Choose professional testing to make every beam of light precise and every performance perfect.

Online Message

Name
Phone
WhatsApp

WhatsApp

E-mail

E-mail

WeChat

WeChat

二维码Scan WeChat
TOP